Bay Networks CM 100 Bedienerhandbuch Seite 58

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 66
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 57
B-4 893-839-C
Attaching the Terminal Leads
Required tool: Flat-tip screwdriver
1. Pry off the terminal safety cover with a
flat-tip screwdriver.
2. Loosen the terminal post screws.
WARNING: Ensure that the DC power source is OFF or disconnected on the remote end
before you connect the terminal leads to the hub. This task may involve switching a circuit
breaker, or powering the DC input source to OFF.
Redundant
Power
CAUTION
!
!
This unit has more than one D.C. power supply input.
To reduce the risk of high energy levels and/or fire hazard
disconnect both D.C. power cords prior to service.
40-56 VDC, 2.0-1.5A
Redundant Power
+12 VDC @ 1.6A
–12 VDC @ 0.5A
+5 VDC @ 7A
+
7066
7070
3. Attach 14-22 AWG positive, negative, and
ground leads to the terminal posts as indi-
cated on the faceplate of the 100-series hub.
4. Tighten the terminal post screws to secure
the leads.
7071
7072
893-839-CBook Page 4 Thursday, December 12, 1996 4:18 PM
Seitenansicht 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 64 65 66

Kommentare zu diesen Handbüchern

Keine Kommentare