Nortel Switch User Authentication
Technical Configuration Guide v1.0 NN48500-589
___________________________________________________________________________________________________________________________
Nortel Confidential Information Copyright © 2009 Nortel Networks. All Rights Reserved.
External Distribution
47
At minimum, verify the following items:
Option Verify
Authentication Result If successful, Authenticated should be displayed. If not, verify the
device using the previous step and if this also fails, verify the Ignition
Server configuration.
Authorization Result If successful, Allow should be displayed. If not, verify the device using
the previous step and if this also fails, verify the Ignition Server
configuration.
User-Name Displays the name of the user id, in this example, a user id of 8600rwa
was used for the user with read-write-all-access rights.
Access Policy This field displays the Ignition Server policy used for this user which
should be ERS8600-Acess as configured for this example.
Policy Rule Used
Outbound Attribute
For this user, the Policy rule read-write-all-access as configured above
should be used which sends an outbound vendor specific attribute
value of 6 to the ERS8600 telling the switch this user has read-write-all-
access