Installing and Operating BayStack ARN Routers
1-6
114200-D Rev 00
Rack-Mounting the ARN
For this procedure, you need:
Two flange brackets and eight #6 Phillips screws (shipped with the ARN)
A Phillips screwdriver
An electronic enclosure rack. If the rack does not have threaded rail holes, you
must attach the four cage nuts shipped with the ARN.
Four #10 cagenut screws and washers (shipped with the ARN)
To rack-mount the ARN:
1.
Determine how you want the ARN to fit in the equipment rack.
Multiple holes in the flange brackets provide several options for
rack-mounting the ARN. How you attach the flange brackets determines how
far the router extends outside or remains inside the rack. Figure 1-2
shows
three of the most common locations for the brackets.
2.
Attach a flange bracket to each side of the ARN.
a.
Align four bracket holes with four holes in the ARN enclosure
(Figure 1-2)
.
b.
Insert a #6 Phillips screw through each hole and into the ARN.
c.
Tighten the four screws with a Phillips screwdriver.