Using Technician Interface Software
8-84
303561-A Rev 00
Example
The following command retrieves the circuit number (attribute 5) for every entry
in the IP Interface table:
$ g wfIpInterfaceEntry.5.*
wfIpInterfaceEntry.wfIpInterfaceCircuit.192.32.174.33.3 = 3
wfIpInterfaceEntry.wfIpInterfaceCircuit.192.32.174.66.4 = 4
wfIpInterfaceEntry.wfIpInterfaceCircuit.192.32.174.98.2 = 2
wfIpInterfaceEntry.wfIpInterfaceCircuit.192.32.175.66.1 = 1
The instance ID for each entry in this case is <IP_address.circuit_number>.
Example
The following command retrieves the circuit number (attribute 2) for every entry
in the Circuit Name table:
$ g wfCircuitNameEntry.2.*
wfCircuitNameEntry.wfCircuitNumber.1 = 1
wfCircuitNameEntry.wfCircuitNumber.2 = 2
wfCircuitNameEntry.wfCircuitNumber.3 = 3
wfCircuitNameEntry.wfCircuitNumber.4 = 4