Parameter: Host Time Seq Enable
Attribute Name: wfSyslogLogTimeSeqEnable
Attribute Number: 6
Default: 2 (Disable)
Options: 1 (Enable)
|
2 (Disable)
Function: Enables or disables time sequencing and forwarding of Syslog (event)
messages to the remote host associated with this host entry.
Instructions: Enable this feature only if the remote host must receive Syslog messages
in the order in which they were logged on the router.
When you enable this feature, Syslog on each slot
Polls the local events log
Retrieves messages from the local log
Filters the messages
Time-sequences messages that pass through the filters
Forwards sequenced messages to IP on the router, which in turn
forwards the messages to the remote host associated with this entry
When you disable this feature, Syslog on each slot
Polls the local events log
Retrieves messages from the local log
Filters the messages
Forwards sequenced messages to IP on the router, which in turn
forwards the messages to the remote host associated with this entry
Command:
set wfSyslogHostEntry.wfSyslogLogTImeSeqEnable.
<host_IP_address>
<1
|
2>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.2.1.6